When choosing an adhesive, you are likely to consider a number of factors: ease of application, versatility and compatibility with different restorative materials. But ultimately, one question matters most: How reliable is the bond between the tooth and the restoration? One important indicator is shear bond strength. It is one of the most commonly used laboratory parameters for evaluating adhesive bonds and indicates how much load a bond can withstand under defined conditions. 

What exactly is shear bond strength? 

Put simply, shear bond strength describes the load an adhesive bond can withstand before it fails. In a shear test, a lateral force is applied largely parallel to the bonded surface. You can picture this as two bonded surfaces being pushed past one another. This is the principle behind shear bond strength testing of dental adhesives.

How is shear bond strength measured?

In simple terms, the test can be broken down into three steps:

Not just when, but where the bond fails

The failure mode can provide additional information. Common types include:

• adhesive failure: failure at the interface between the tooth and the adhesive
• cohesive failure: failure within the dentin, enamel or restorative material
• mixed failure: a combination of different failure modes

How should bond strength values be interpreted?  

A high bond strength value does not automatically mean that the adhesive is clinically superior. The measured result depends on a number of factors, including the tooth substrate, etching technique, dentin moisture, restorative material, polymerisation and test method. Shear tests also generate local stress concentrations at the adhesive interface. A single bond strength value therefore provides only a simplified representation of the complex stresses that occur in the mouth.

The key question therefore is not just how high a bond strength value is, but also under what conditions it was actually obtained.
Bond strength values are particularly meaningful when different materials or conditions – such as varying moisture levels – are compared within the same clearly defined test protocol.[1]
As a rough guide, literature reports bond strength values of around 17 MPa as sufficient to counteract the shrinkage forces generated during composite polymerisation.[2] However, this figure should not be regarded as a stand-alone threshold for clinical success. 
There is no generally accepted bond strength value above which a restoration can automatically be considered clinically successful. 

At Ivoclar, bond strength values are therefore always assessed in the context of the respective test protocol and on the basis of many years of experience in the development and testing of dental adhesives.

"A single measurement never tells the whole story. A good product has to perform well across a range of parameters in the laboratory, deliver convincing results in preclinical testing and prove itself in everyday clinical practice." 

Dr Barbara Rietzler-Lins, Head of Department Adhesives & Temporary Materials at Ivoclar

What does bond strength mean in clinical practice?  

Stable adhesion to the tooth is a key prerequisite for the long-term success of adhesive restorations.

A shear test provides a simplified simulation of stresses that may occur at the adhesive interface in clinical practice, for example as a result of masticatory forces. In the mouth, however, these forces do not occur in isolation, but together with tensile and compressive loads. 

For dentists, it is therefore usually less important whether an adhesive achieves a few megapascals more under ideal conditions. More informative is how reliably the bond performs under various clinically relevant conditions. This is precisely what was investigated with Adhese 2.

Did you know?

Bite forces of about 450–600 N can occur in the molar region. This is roughly equivalent to the force exerted by a mass of 45–60 kg.[3]

Adhese 2 put to the test: How stable is the bond under different conditions? 

What role does the etching protocol play? 

The study investigated: 
The shear bond strength of Adhese 2 with Tetric plus on dentin and enamel using the etch-and-rinse and self-etch techniques. 

What does this mean in practice? 
In combination with Tetric plus, Adhese 2 achieved high bond strength values with both the etch-and-rinse and self-etch techniques.
The results support a flexible choice of etching technique based on the clinical situation.

How sensitive is the bond to moisture?

The study investigated: 
The shear bond strength of Adhese 2 with Tetric PowerFill using the self-etch technique on dry and wet dentin. 

What does this mean in practice?  
Dentin is naturally a moist substrate. In the test, Adhese 2 demonstrated high moisture tolerance and achieved high bond strength values on both dry and wet dentin.  

Please note: Moisture tolerance does not mean ‘wet bonding’ or bonding without isolation. Adequate isolation and correct application of the adhesive remain essential.

What happens when Adhese 2 is used in self-cure mode without light-curing?  

The study investigated: 
The shear bond strength of Adhese 2 with Variolink Esthetic DC on dentin and enamel when used in self-cure mode using the self-etch technique. 

What does this mean in practice? 
Adhese 2 achieved high bond strength values even when used in self-cure mode, as may be required, for example, during the adhesive cementation of indirect restorations. 

Important: To use Adhese 2 in self- or dual-cure mode, the blue DC cannula must be used together with a dual-curing luting composite, such as Variolink Esthetic DC. 

Does a high bond strength automatically mean a long-lasting restoration?

Initial shear bond strength alone does not provide direct evidence of a restoration’s long-term clinical success. In the oral cavity, the adhesive bond is exposed over time to moisture, temperature fluctuations and mechanical stresses. Laboratory tests therefore attempt to simulate at least some of these conditions by means of artificial aging. One established method is thermocycling. During thermocycling, specimens are repeatedly transferred between warm and cold water baths to simulate thermal stresses similar to those occurring in the oral cavity.  The bond strength is then reassessed to determine how it has changed.

How does artificial aging affect the bond strength of Adhese 2? 

For the Adhese 2 investigation, the specimens were first stored in water at 37 °C for 24 hours and then subjected to 10,000 temperature cycles between 5 °C and 55 °C.
Shear bond strength on enamel and dentin with Tetric® PowerFill using the self-etch (SE) technique after artificial aging: 

What does the test show? 

Even after 10,000 temperature cycles, the adhesive bond to enamel and dentin remained stable under the conditions tested, indicating good long-term stability. 

Interpreting bond strength values correctly: 3 key points

Evaluate long-term stability

Shear bond strength alone does not provide direct evidence of longevity.

After artificial aging, for example by means of thermocycling, it can nevertheless provide an indication of the long-term stability of the bond. 

Always compare bond strength values in context

Comparability is more important than a single peak value.

A single high value is less informative than reliable bonding under different conditions, such as changes in dentin moisture or the use of different etching techniques. Wherever possible, values should be compared within the same test protocol.

Take clinical factors into account

Modern universal adhesives need to do more than perform under one ideal set of conditions. They should provide confidence, flexibility and predictable results across a wide range of treatment situations. Adhese 2 was developed with exactly this in mind – to provide dentists with reliable bonding across a broad range of everyday clinical applications. 

Would you like to take a look behind the scenes? 
Watch the video to find out more about how Adhese 2 was developed and tested. 

Clinical success results from the interaction of numerous factors.

Bond strength values are only one part of the overall picture. Isolation, correct application, polymerisation, the material combination and the specific clinical situation all influence the adhesive bond. Therefore, the adhesive should always be used in accordance with the manufacturer's instructions.

Modern universal adhesives need to do more than perform under one ideal set of conditions. They should provide confidence, flexibility and predictable results across a wide range of treatment situations. Adhese 2 was developed with exactly this in mind – to provide dentists with reliable bonding across a broad range of everyday clinical applications. 

Would you like to take a look behind the scenes? Watch the video to find out more about how Adhese 2 was developed and tested. 