EN(AU)
Choose language
Change region
Choose your country Come visit our site in your country! Choose your region from the list below:
    Choose language
    Go
    Choose your country Come visit our site in your country! Choose your region from the list below:
      Choose language
      Go
      This product is not available for purchase by general public. Always follow the directions for use.
      Lab

      IPS e.max CAD PrograMill Block HT I12 / 5
      BL3


      686561
      Go to downloads
      All variants
      Contact Us Request for quote Login to view price
      Product replaced by
      Back to overview Request for quote
      Variants
      A1
      686563
      Add to cart
      A2
      686564
      Add to cart
      A3
      686565
      Add to cart
      A3.5
      686566
      Add to cart
      A4
      686567
      Add to cart
      B1
      686568
      Add to cart
      B2
      686569
      Add to cart
      B3
      686570
      Add to cart
      B4
      686571
      Add to cart
      BL1
      686559
      Add to cart
      BL2
      686560
      Add to cart
      BL3
      686561
      Add to cart
      BL4
      686562
      Add to cart
      C1
      686572
      Add to cart
      C2
      686573
      Add to cart
      C3
      686574
      Add to cart
      C4
      686575
      Add to cart
      D2
      686576
      Add to cart
      D3
      686577
      Add to cart
      D4
      686578
      Add to cart
      Description Ratings & Reviews (0)
      Description
      Description

      Lithium disilicate glass-ceramics (LS2)

      IPS e.max® CAD is the best-selling glass-ceramic[1] worldwide. The material enables the efficient fabrication of full-contour restorations. It is distinguished by its flexibility, versatile field of applications and processing options and its high strength of 530 MPa.[2]

      Both its aesthetic properties and durability have been confirmed in everyday clinical practice.[3-5]

      Processing options:
      “Blue” restorations can be:

      • Polished and crystallised
      • Glazed and crystallised in a single step
      • Stained, glazed and crystallised in a single step

      Types of restorations:

      • Minimally invasive crowns (1mm)[6]
      • Crowns
      • Three-unit bridges (up to the second premolar as the terminal abutment)
      • Implant-supported hybrid abutment restorations (hybrid abutments[7], hybrid abutment crowns)
      • Veneers and occlusal veneers
      • Inlays, onlays, partial crowns

      Benefits:

      • Excellent aesthetics and high flexural strength of 530 MPa[2]
      • 97.2% survival rate of posterior crowns over a period of 10 years[8]
      • Efficient grinding and crystallisation of posterior crowns in only 19:17 minutes[9]
      • Broad spectrum of restorations for your chairside CAD/CAM applications
      • 10-year guarantee
      • Suitable for conventional, adhesive or self-adhesive cementation techniques

      Block sizes[7]:

      • 6 (I12, C14, C16, B32, B40 and B40 L) and 2 abutment block sizes (A14, A16)

      Translucency levels[7]:
      Given their high translucency, HT blocks are ideally suited for the fabrication of small restorations (e.g. inlays, onlays). Restorations made from HT blocks blend in naturally with their surroundings due to their chameleon effect.[10]

      • 4 levels and 2 Impulse blocks (HT - High Translucency, MT - Medium Translucency, LT - Low Translucency, MO - Medium Opacity)

      Shades[7]:

      • Comprehensive range of shades: in A-D and BL shades (the range of shades varies depending on the translucency level).

      Authorised CAD/CAM systems:

      Ivoclar:

      • PrograMill® PM3 / PM5 / PM7
      • Zenotec® Select Hybrid

      Amann Girrbach:

      • Ceramill® mikro ic
      • Ceramill® motion 2 / motion 3 /drs
      • Ceramill® matik

      Planmeca:

      • PlanMill® 30 S / 40 / 40 S

      Dentsply Sirona:

      • inLab® MC XL / MC X5
      • CEREC® MC / MC X / MC XL / Primemill

       

      [1] Based on global sales figures.
      [2] Average biaxial flexural strength, Outcome after more than 10 years of ongoing quality testing, R&D Ivoclar, Schaan.
      [3] Fasbinder D. J et al., Study report, 2017b.
      [4] Rauch A et al., Clin. Oral Investig. 2018, 22, p. 1763-1769.
      [5] Boldt J, Spitznagel F. A, Dtsch. Zahnaerztl. Z. 2017, 72 (4), p. 319-325.
      [6] Long-term clinical evidence and the material’s high strength allows the recommendation for crowns with a minimum layer thickness of 1mm in combination with an adhesive cementation method.
      [7] The offering varies, depending on the CAD/CAM system being used.
      [8] The survival rate of monolithic IPS e.max CAD posterior crowns was evaluated with the Kaplan-Meier method. The failure rate refers to technical failures such as fractures and chipping, R&D Ivoclar, Schaan.
      [9] Average grinding time of three posterior crowns, 08:07 minutes (CEREC Primemill, fast grinding mode), followed by superspeed crystallisation in the Programat CS6, 11:10 minutes (HT, MT, LT / glaze spray or polishing technique),
      maximal two restorations, R&D Ivoclar, Schaan.

      [10] At natural lighting conditions. LED-generated UV or UV-like light may result in a different impression.
       
      CEREC®, inLab®, PlanMill® and ceramill® are not registered trademarks of Ivoclar Vivadent AG.

      Ratings & Reviews (0)
      No reviews on this product available. Be the first to write a review!
      We can not publish your review if it contains:
      Personal information Detailed information on prices, promotions, shipping and customer service Information about other companies and websites
      Related products

      Add to favorites

      Please choose a list or create a new one to add the product to favorites.
      Choose your list

      Upgrade your account to perform your requested action

      With your current account profile you cannot benefit from the full range of the Ivoclar Customer Portal functionality. Please upgrade your account for free.